FAN Lin-jun,JIANG Jun,YANG Xin-hua,FAN Li,ZHANG Yi.Locating parathyroid adenoma by combination of 99Tcm-methoxy isobutyl isonitrile and γ-prober[J].J Amry Med Univ (J Third Mil Med Univ),2007,29(02):170-172.
FAN Lin-jun,JIANG Jun,YANG Xin-hua,FAN Li,ZHANG Yi.Locating parathyroid adenoma by combination of 99Tcm-methoxy isobutyl isonitrile and γ-prober[J].J Amry Med Univ (J Third Mil Med Univ),2007,29(02):170-172.DOI:
Locating parathyroid adenoma by combination of 99Tcm-methoxy isobutyl isonitrile and γ-prober
Objective To evaluate the effect of γ-prober in locating parathyroid adenoma during operation. Methods Of 15 cases with parathyroid adenoma definitely diagnosed in Department of Endocrinology
2 were male and 13 were female
with mean age of 41 (range 17-63) years and mean serum calcium 2.94 (range 2.76-3.43) mmol/L. The routine surgical exploration was applied in 12 cases.
99
Tc
m
-methoxy isobutyl
isonitrile (MIBI) at 0.555 GBq was administered intravenously an hour before operation in the other 3 cases and γ-prober was used for the nuclide hot spot following surgical exploration
then parathyroid adenoma was excised. Results Of 15 cases
parathyroid adenoma was found in the right in 11 cases and in the left in 4 cases; at superior parathyroid gland in 2 cases
at inferior parathyroid gland or below thyroid gland in 13 cases. Of 12 cases subject to routine surgical exploration
the focus was found and removed by reoperation in one case due to the location variation
and their average operation time was 165(range 120-240) min. With γ-prober
parathyroid adenoma was found below thyroid gland in all 3 cases
and their operation time was respectively 95
105
and 110 min. The serum calcium was below the normal level on postoperative day 1 and restored to the normal by intaking calcium orally or intravenously for about a week. Of 15 cases
11 cases were followed up for 3 months to 10 years
and the main manifestations before operation were relieved. Conclusion The combination of
99
Tc
m
-MIBI admininstered preoperatively and γ-prober used during operation can locate parathyroid gland accurately
which avoids blind exploration and repeated frozen section during operation